Fastener Products

Product Details

AR Chemical Setter MU Anchor MU

For Concrete / Hammer Drive type
  • L-shaped rebar / U-shaped rebar can be installed.
  • Demonstrates strong fixing force just by driving.
  • Better to use rod or deformed bar with thread.
  • High bond strength can be obtained by using a metal wire brush.
  • Uses the included stopper to prevent liquid splashing and dripping.
  • Can be installed on walls and ceilings.
[Application]
Joint Bars for Extension and Reconstruction / Accommodation Ladder Installation/ L-shaped・U-shaped Rebar / Car Stop / Equipment / Antenna

❶Drill a hole
❷Clean the hole 2 to 3 times
❸Mark on the anchor rod
❹Attach fixing elements after required curing time
●If the installation temperature is 5 ° C or less, immediately rotated the rod 5 turns or more. Do not use in an environment below -5 ° C.
●Please use the included stopper for installation on the ceiling surface.
●When installing on the wall or ceiling, be careful of liquid dripping.
●Be sure to observe the expiration date (3 years from manufacturing).
❺After curing time, attach fixing elements
・Estimated Curing Time
Temperature (℃) -5 0 5 10 15 20 25 30
Curing time (Minute) 360 180 120 70 45 30 25 20
※This curing time is a guideline for achieving a about 80% of maximum strength

MU Type

強度表をPDFで開く
Unit:mm Unit:kN
Bolt Item no. Drilling depth Allowable tensile load
(long term)
Allowable tensile load
(short term)
M 8 MU-8 70 5.9 8.9
M10 MU-10 90 9.4 14.2
M12 MU-12 110 13.7 20.6
M16 MU-16 140 25.3 38.0
M20 MU-20 170 38.3 57.5
Unit:mm Unit:kN
Deformed bar Item no. Drilling depth Allowable tensile load
(long term)
Allowable tensile load
(short term)
D10 MU-10 90 10.1 15.2
D13 MU-12 110 16.1 24.2
D16 MU-16 140 25.3 38.0
D19 MU-20 170 36.5 54.7
・The allowable load varies depending on the rod material, type, concrete strength, and embedding conditions. Please calculate the strength according to the actual installation conditions.
・Proceed installation with a metal wire brush.
・The allowable tensile load is a calculated value according to the manufacturer’s formula. The allowable load is the calculated value of the concrete failure mode when using Fc = 21N / mm2 concrete, M screws (SS400) and deformed bar SD295 (use SD345 for above D19)
※Capsule length and drilling depth of M16 are not the same

MU TYPE / GLASS CAPSULE: VINYL ESTER RESIN
… JCAA Certified …SHASE-S Standard
サイズ表をPDFで開く

Open chart in PDF

Unit:mm Unit:pc
D Item no. L Content
Threaded Rod
Deformed bar
Drilling
diameter
Drilling depth Qty・per
Box Medium box Carton
8.0 MU-8 70 2.9 M8 9.5 70 5 100 1,000
10.5 MU-10 90 6.0 M10 12.0 90 20 100 1,000
10.5 MU-10 90 6.0 D10 12.5 90 20 100 1,000
13.0 MU-12 110 11.0 M12 15.0 110 20 100 1,000
13.0 MU-12 110 11.0 D13 16.0 110 20 100 1,000
16.5 MU-16 120 23.0 M16 19.0 140 20 100 500
16.5 MU-16 120 23.0 D16 20.0 140 20 100 500
18.0 MU-20 170 35.0 M20 23.0 170 10 50 200
18.0 MU-20 170 35.0 D19 23.0 170 10 50 200

【Drilling】
Anchor Drill Bit [ADXⅡ-HEX Type] [ADXⅡ-MAX Type]
【Cleaning】
Dust Pump [P Type]
Dust Brush [AW Type]
Dust Brush [W Type]
【Marking】
【Insert/Installation】
Anchor Hammer Type [AH Type]